Clearance Specials
Apollo 20 Low Pressure (LP) Supplied-Air Respirators
Apollo LP Low-Pressure Respirators and Accessories
For use with ambient air pump.
The Apollo 20 LP is a Type CE, continuous flow, supplied-air respirator with Constant-Flow Connector for abrasive blasting, to be used with an ambient air pump. The high visibility red single-shell helmet has a box-front window, and a protective cape.
The Apollo 20 LP is a Type CE, continuous flow, supplied-air respirator with Constant-Flow Connector for abrasive blasting, to be used with an ambient air pump. The high visibility red single-shell helmet has a box-front window, and a protective cape.
Unit of Measure
Items |
/Asset/Apolo-LP20.gif 21299 Apollo 20 Low Pressure (LP) Supplied-Air Respirator with Less Respirator Hose and Constant-Flow Connector Price $710.00
|
/Asset/Apolo-LP20.gif 21423 Apollo 20 Low Pressure (LP) Supplied-Air Respirator with 50 Feet (ft) Respirator Hose and Constant-Flow Connector Price $815.00
|
/Asset/Apolo-LP20.gif 22690 Apollo 20 Low Pressure (LP) to 20 High Pressure (HP) Conversion Kit Price $295.00
|
/ImgCustom/1003/placeholder_notavailable.gif 23886 Noise-Reduction Ear Muff Price $114.00
|
/ImgCustom/1003/placeholder_notavailable.gif 23814 Clemco® Do-Rags Price $29.50
|
|||||
Brands | N/A Apollo | N/A Apollo | N/A Apollo | N/A Apollo | N/A Clemco® | |||||
Manufacturer |
N/A
CLEMCO |
N/A
CLEMCO |
N/A
CLEMCO |
N/A
CLEMCO |
N/A | |||||
Hose I.D. | N/A | N/A 1/2 in | N/A | N/A | N/A | |||||
Hose Length | N/A | N/A 50 ft | N/A | N/A | N/A | |||||
Image Reference Number | N/A | |||||||||
Weight | N/A 6.5 lb | N/A 16.5 lb | N/A 7 lb | N/A <0.5 lb | N/A <0.5 lb | |||||
Requirement for Operation |
N/A
The following items are required or recommended for operation, but are not included with this respirator:
|
N/A
The following items are required or recommended for operation, but are not included with this respirator:
|
N/A | N/A | N/A | |||||
Description of Operation |
N/A
|
N/A
|
N/A | N/A | N/A | |||||
Advantages |
N/A
|
N/A
|
N/A | N/A | N/A | |||||
Approval and Certifications | N/A The Apollo 20 LP helmet is a NIOSH approved type CE respirator (approval number TC-19C-339) and is recognized by OSHA as having an assigned protection factor (APF) against lead dust of 1000 times the permissible exposure limit (PEL). | N/A The Apollo 20 LP helmet is a NIOSH approved type CE respirator (approval number TC-19C-339) and is recognized by OSHA as having an assigned protection factor (APF) against lead dust of 1000 times the permissible exposure limit (PEL). | N/A | N/A | N/A | |||||
Related Clemco Literature | N/A Abrasive Blasting Safety Practices (22090) Apollo 20 LP Owner's Manual (21991) Blast off 2 (09294) Contractor Series Catalog (21385) Operator Safety Equipment Product Study (07764) | N/A Abrasive Blasting Safety Practices (22090) Apollo 20 LP Owner's Manual (21991) Blast off 2 (09294) Contractor Series Catalog (21385) Operator Safety Equipment Product Study (07764) | N/A | N/A | N/A | |||||
Options & Accessories | N/A Blast hose safety cable (15013) Heavy-duty blast suit (leather front, cotton back) (08920) - Small Heavy-duty blast suit (leather front, cotton back) (08921) - Medium Heavy-duty blast suit (leather front, cotton back) (08922) - Large Heavy-duty blast suit (leather front, cotton back) (08923) - XL Heavy-duty blast suit (leather front, cotton back) (24201) - XXL Heavy-duty blast suit (leather front, cotton back) (24202) - XXXL Leather gloves (02243) Light-weight seasonal blast suit (Nylon front, cotton back) (22913) - Small Light-weight seasonal blast suit (Nylon front, cotton back) (22914) - Medium Light-weight seasonal blast suit (Nylon front, cotton back) (22915) - Large Light-weight seasonal blast suit (Nylon front, cotton back) (22916) - XL Light-weight seasonal blast suit (Nylon front, cotton back) (22917) - XXL Light-weight seasonal blast suit (Nylon front, cotton back) (25022) - XXXL | N/A Blast hose safety cable (15013) Heavy-duty blast suit (leather front, cotton back) (08920) - Small Heavy-duty blast suit (leather front, cotton back) (08921) - Medium Heavy-duty blast suit (leather front, cotton back) (08922) - Large Heavy-duty blast suit (leather front, cotton back) (08923) - XL Heavy-duty blast suit (leather front, cotton back) (24201) - XXL Heavy-duty blast suit (leather front, cotton back) (24202) - XXXL Leather gloves (02243) Light-weight seasonal blast suit (Nylon front, cotton back) (22913) - Small Light-weight seasonal blast suit (Nylon front, cotton back) (22914) - Medium Light-weight seasonal blast suit (Nylon front, cotton back) (22915) - Large Light-weight seasonal blast suit (Nylon front, cotton back) (22916) - XL Light-weight seasonal blast suit (Nylon front, cotton back) (22917) - XXL Light-weight seasonal blast suit (Nylon front, cotton back) (25022) - XXXL | N/A | N/A | N/A | |||||
Application Alert | N/A Respirators are not approved for use in any atmosphere immediately dangerous to life or health or from which the wearer cannot escape without the aid of the respirator. Before using any respirator, make sure that any airborne contaminants are not in concentrations that are in excess of those allowed by applicable OSHA or EPA regulations or NIOSH recommendations. Consult the product literature and owner's manuals for information concerning the proper function, use, and maintenance of these respirators. Always recommend carbon monoxide (CO) monitors. | N/A Respirators are not approved for use in any atmosphere immediately dangerous to life or health or from which the wearer cannot escape without the aid of the respirator. Before using any respirator, make sure that any airborne contaminants are not in concentrations that are in excess of those allowed by applicable OSHA or EPA regulations or NIOSH recommendations. Consult the product literature and owner's manuals for information concerning the proper function, use, and maintenance of these respirators. Always recommend carbon monoxide (CO) monitors. | N/A | N/A Respirators ARE NOT approved for use in any atmosphere immediately dangerous to life or health or from which the wearer cannot escape without the aid of the respirator. Before using any respirator, make sure that any airborne contaminants ARE NOT in concentrations that are in excess of those allowed by applicable OSHA or EPA regulations or NIOSH recommendations. Consult the product literature and owner's manuals for information concerning the proper function, use, and maintenance of these respirators. | N/A | |||||
Purpose | N/A The Apollo 20 LP is designed for use with an ambient air pump. It meets OSHA standards for respiratory protection and noise limitations. The Apollo 20’s full-helmet design and heavy-duty cape protect the blast operator’s head, neck, shoulders, and chest from rebounding abrasive. | N/A The Apollo 20 LP is designed for use with an ambient air pump. It meets OSHA standards for respiratory protection and noise limitations. The Apollo 20’s full-helmet design and heavy-duty cape protect the blast operator’s head, neck, shoulders, and chest from rebounding abrasive. | N/A | N/A | N/A | |||||
Note |
N/A
All Apollo 20s come with DLX and web suspensions; DLX suspension installed. For use with ambient air pump. Color Changed to Green In 2007. The Occupational Safety and Health Administration (OSHA) has Assigned Apollo Helmets a Protection Factor of 1,000 Times the Exposure Limit for Lead Dust. Prior to use, ensure that the Apollo, type CE, supplied-air respirator is appropriate for your specific blasting conditions and requirements. For safe, efficient blasting, read and follow the owner's manual and seek training for everyone who will use this equipment. |
N/A
All Apollo 20s come with DLX and web suspensions; DLX suspension installed. For use with ambient air pump. Color Changed to Green In 2007. The Occupational Safety and Health Administration (OSHA) has Assigned Apollo Helmets a Protection Factor of 1,000 Times the Exposure Limit for Lead Dust. Prior to use, ensure that the Apollo, type CE, supplied-air respirator is appropriate for your specific blasting conditions and requirements. For safe, efficient blasting, read and follow the owner's manual and seek training for everyone who will use this equipment. |
N/A | N/A For use with compressed air source. | N/A For use with compressed air source. | |||||
|