Clearance Specials
  • For dusty applications or when using metallic grit (maximum G-50) or shot (maximum S-170), reclaimers rated at 900 cfm are recommended.
  • CDC collectors are serviced from the top, requiring additional height allowance for replacing the filter cartridge.
  • For steel applications, flex hose, and adaptors must be sized appropriately. Optional rubber curtains recommended. See “M” models for steel-ready cabinets.
Unit of Measure

Specifications

Reclaim

N/A 600 CFM17 m³/m

Dust Collection

N/A Dust Bag

Single Phase

N/A 19945

Three Phase

N/A 19946

Dust Collectors

N/A Dry Filters:
Dry filters are suitable for most industrial applications where the dust collector can be shut off periodically to shake dust from the 100% cotton sateen filter tubes. Dry filters trap 98% of dust down to 1.0 micron.

  • 5 sq. ft. filter area per tube
  • 300 cfm DF has 15 tubes (75 sq. ft.)
  • 600 cfm DF has 25 tubes (125 sq. ft.)

  • Electrical

    N/A 600 CFM (17 m3/m) 1HP, 115V, 1PH, 60HZ, (.75KW, 220V, 1PH, 50HZ); available with either single phase or three phase motors.
    For three phase motors, specify 230v or 460v.