Clearance Specials
Panel Mounted Airline Monitors
AIR SYSTEMS INTERNATIONAL
For Fixed System Continuous Sampling of CO and/or CO/O2 levels
The carbon monoxide (CO) airline monitor panel can be ordered to retrofit any existing Grade-D breathing air system, CO and Oxygen (O2) monitor also available. Standard units are supplied with high intensity audible alarm (120 dBA) and a 115 VAC power cord. All units are powder coated steel and ready for wall mounting. Intrinsically safe versions available - CSA approved, 9 VDC power only. Supplied Grade-D air filtration is required to operate the monitor.
The carbon monoxide (CO) airline monitor panel can be ordered to retrofit any existing Grade-D breathing air system, CO and Oxygen (O2) monitor also available. Standard units are supplied with high intensity audible alarm (120 dBA) and a 115 VAC power cord. All units are powder coated steel and ready for wall mounting. Intrinsically safe versions available - CSA approved, 9 VDC power only. Supplied Grade-D air filtration is required to operate the monitor.
Unit of Measure
Items |
/Asset/CO-91PM.png CO-91PM Panel Mounted Carbon Monoxide (CO) Monitor Price $1,395.00
|
/Asset/CO-91PM.png CO2-91PM Panel Mounted Carbon Monoxide (CO) and Oxygen (O2) Monitor Price $1,895.00
|
/Asset/CO-91PM.png CO-91PMIS Panel Mounted Intrinsically Safe Carbon Monoxide (CO) Monitor Price $1,395.00
|
/Asset/BBK-20.png BBK-20 Calibration Kit for 20 Parts Per Million (ppm) Carbon Monoxide (CO) Monitor Price $220.00
|
/ImgCustom/1003/placeholder_notavailable.gif BBK-10 Calibration Kit for 10 Parts Per Million (ppm) Carbon Monoxide (CO) Monitor Price $220.00
|
|||||
Description |
N/A
Panel Mounted Airline Monitors for Grade-D Air Filtration Audible alarm, visual lights, flow meter, quick connect calibration fitting. |
N/A
Panel Mounted Airline Monitors for Grade-D Air Filtration Audible alarm, visual lights, flow meter, quick connect calibration fitting. |
N/A
Panel Mounted Airline Monitors for Grade-D Air Filtration Audible alarm, visual lights, flow meter, quick connect calibration fitting. |
N/A
Small Cylinders 20 ppm CO, zero air, regulator, tubing, and hard case, 17 liter size disposable cylinders. |
N/A
Small Cylinders 10 ppm CO, zero air, regulator, tubing, and hard case, 17 liter size disposable cylinders, for Canadian CO monitor settings. |
|||||
Brands | N/A Kleen Blast | |||||||||
Direct Current (DC) Voltage | N/A 9 V | |||||||||
Power Cord Alternating Current (AC) Voltage | N/A 115 V | |||||||||
Optional Alternating Current (AC) Voltage | N/A 230 V | |||||||||
Monitor Display | N/A Liquid Crystal Display (LCD) | N/A Liquid Crystal Display (LCD) | N/A Liquid Crystal Display (LCD) | N/A | N/A | |||||
Country of Origin | N/A USA | |||||||||
Weight | N/A | |||||||||
Certification | N/A CSA Approved for Class I, Division 1, Groups C and D environments (9 VDC operation only) | |||||||||
How Often Should I Calibrate The Monitor? | N/A | N/A | N/A |
N/A
Air Systems recommends calibrating our CO and CO/O2 Series breathing air monitors monthly. If monthly calibrations are not followed, the monitor should be recalibrated at least every six months from the last calibration prior to use. Zero Air - When calibrating the monitor, Zero Air is used to achieve a true zero reading on the monitor before using the Carbon Monoxide (CO) test gas. Zero air removes all background interference gasses. Carbon Monoxide (CO) - Use only 10-20 ppm CO gas for calibration. Using a higher CO concentration may decrease accuracy at lower scale readings. Note: 10 ppm gas must be used to satisfy Canadian calibration requirements. Oxygen (O2) - For CO/ O2 monitor, use only 20.9% oxygen in nitrogen gas for calibration. |
N/A
Air Systems recommends calibrating our CO and CO/O2 Series breathing air monitors monthly. If monthly calibrations are not followed, the monitor should be recalibrated at least every six months from the last calibration prior to use. Zero Air - When calibrating the monitor, Zero Air is used to achieve a true zero reading on the monitor before using the Carbon Monoxide (CO) test gas. Zero air removes all background interference gasses. Carbon Monoxide (CO) - Use only 10-20 ppm CO gas for calibration. Using a higher CO concentration may decrease accuracy at lower scale readings. Note: 10 ppm gas must be used to satisfy Canadian calibration requirements. Oxygen (O2) - For CO/ O2 monitor, use only 20.9% oxygen in nitrogen gas for calibration. |
|||||