Clearance Specials
Breather Box® Portable Grade-D Breathing Air Filtration Systems
AIR SYSTEMS INTERNATIONAL
The Industry Standard in Grade-D Air Filtration
Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available.
Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available.
Unit of Measure
Items |
/ImgCustom/1003/placeholder_notavailable.gif BB15-CO Breather Box® 15 Cubic Feet Per Minute (ft³/min) Air Flow and 1 Couplings Portable Grade-D Breathing Air Filtration System with CO Monitor Price $1,750.00
|
/Asset/BB30-CO-Image.jpg BB30-CO Air Systems BB30-CO Breathing Air Filtration System Price $1,895.00
|
/ImgCustom/1003/placeholder_notavailable.gif BB30-CO3 Breather Box® 30 Cubic Feet Per Minute (ft³/min) Air Flow and 3 Couplings Portable Grade-D Breathing Air Filtration System with CO Monitor Price $2,095.00
|
/Asset/BB50CO.png BB50-CO Breather Box® 50 Cubic Feet Per Minute (ft³/min) Air Flow and 4 Couplings Portable Grade-D Breathing Air Filtration System with CO Monitor Price $2,095.00
|
/ImgCustom/1003/placeholder_notavailable.gif BB75-CO Breather Box® 75 Cubic Feet Per Minute (ft³/min) Air Flow and 6 Couplings Portable Grade-D Breathing Air Filtration System with CO Monitor Price $2,395.00
|
|||||
Description |
N/A
The Industry Standard in Grade-D Air Filtration Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available. |
N/A
This portable Grade-D filtration systems is designed to provide breathing air for a specific number of workers. The system filters inlet air to provide respirator users Grade-D quality air. The first stage filters bulk water and particulate, second stage coalescing filter eliminates atomized oils, mists, and ultra-fine particulates, third stage removes organic vapors and odors. Filter change indicators are standard on all three stages. Filter efficiency is 99.99 percent.01 microns. A built-in carbon monoxide monitor operates on 9-volt DC, dual 8 - 16 volt DC or 115 VAC for continuous detection. An external alarm and light signals the worker of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet. The Breather Box models is designed to be used in the closed position to prevent internal contamination. Solid aluminum block manifold. 0-160 psi Pressure Gauge. Flowmeter to verify air flow to monitor. Remote DC alarm jack with cover cap.
|
N/A
The Industry Standard in Grade-D Air Filtration Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available. |
N/A
The Industry Standard in Grade-D Air Filtration Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available. |
N/A
The Industry Standard in Grade-D Air Filtration Connected to a mobile or plant compressor, the Breather Box® provides Grade-D breathing air for 1 to 8 users (based on model) and continuously monitors for Carbon Monoxide (CO). CO/O2 and Intrinsically Safe Models are also available. |
|||||
Brands | N/A Breather Box® Kleen Blast | N/A | N/A Breather Box® Kleen Blast | N/A Breather Box® Kleen Blast | N/A Breather Box® Kleen Blast | |||||
Air Flow | N/A 15 ft³/min | N/A | N/A 30 ft³/min | N/A 50 ft³/min | N/A 75 ft³/min | |||||
Flow Capacity | N/A 48 ft³/min | N/A | N/A 48 ft³/min | N/A 79 ft³/min | N/A 97 ft³/min | |||||
Pressure Regulator/Gauge1 | N/A | |||||||||
Couplings | N/A 1 | N/A | N/A 3 | N/A 4 | N/A 6 | |||||
Alternating Current (AC) Voltage | N/A | |||||||||
Frequency | N/A | |||||||||
Pressure Gauge | N/A 0 to 160 psi | N/A | N/A 0 to 160 psi | N/A 0 to 160 psi | N/A 0 to 160 psi | |||||
Maximum Inlet Pressure | N/A 150 psi | N/A | N/A 150 psi | N/A 150 psi | N/A 150 psi | |||||
Country of Origin | N/A USA | N/A | N/A USA | N/A USA | N/A USA | |||||
Weight | N/A | N/A 23 lb | N/A | N/A | N/A | |||||
Certification | N/A CSA Approved for Class I, Division 1, Groups C and D environments (9 VDC operation only) | N/A | N/A CSA Approved for Class I, Division 1, Groups C and D environments (9 VDC operation only) | N/A CSA Approved for Class I, Division 1, Groups C and D environments (9 VDC operation only) | N/A CSA Approved for Class I, Division 1, Groups C and D environments (9 VDC operation only) | |||||
Warranty | N/A 2 Year Warranty on CO Sensor & Monitor | N/A | N/A 2 Year Warranty on CO Sensor & Monitor | N/A 2 Year Warranty on CO Sensor & Monitor | N/A 2 Year Warranty on CO Sensor & Monitor | |||||
Features |
N/A
|
N/A |
N/A
|
N/A
|
N/A
|
|||||
All Breather Box® Portable and Fixed Panel Specifications |
N/A
|
N/A |
N/A
|
N/A
|
N/A
|
|||||
Note |
N/A
When ordering replacement monitors, contact Customer Service and provide the model number and serial number of the filtration unit. This will ensure the proper monitor for your system. The Breather Box® Works with ANY Airline Respirator Brand Specify 1/4" Hansen style or Schrader style respirator couplings when ordering. Other couplings available for an additional charge. Don't forget to order replacement fi lters and monitor calibration kit! |
N/A |
N/A
When ordering replacement monitors, contact Customer Service and provide the model number and serial number of the filtration unit. This will ensure the proper monitor for your system. The Breather Box® Works with ANY Airline Respirator Brand Specify 1/4" Hansen style or Schrader style respirator couplings when ordering. Other couplings available for an additional charge. Don't forget to order replacement fi lters and monitor calibration kit! |
N/A
When ordering replacement monitors, contact Customer Service and provide the model number and serial number of the filtration unit. This will ensure the proper monitor for your system. The Breather Box® Works with ANY Airline Respirator Brand Specify 1/4" Hansen style or Schrader style respirator couplings when ordering. Other couplings available for an additional charge. Don't forget to order replacement fi lters and monitor calibration kit! |
N/A
When ordering replacement monitors, contact Customer Service and provide the model number and serial number of the filtration unit. This will ensure the proper monitor for your system. The Breather Box® Works with ANY Airline Respirator Brand Specify 1/4" Hansen style or Schrader style respirator couplings when ordering. Other couplings available for an additional charge. Don't forget to order replacement fi lters and monitor calibration kit! |
|||||
|